PRODUCTS » Wires & Cables »
Rubber Sheathed Cables
 
 






Description
:
-PUR outer sheath: low adhesion, flame retardant, extremely abrasion resistant,
 halogen-free,  resistant to UV, oil, hydrolysis and microbial attack
-PUR sheath: self-extinguishing and flame retardant, test method B acc. to DIN VDE 0472
 part 804  and IEC 60332-1
-This screened motor power supply cable, with low mutual capacitance because of the
 special PE  core insulation, enables low-loss transmission of power compared to
 PVC-sheathed power   supply cables
-The optimal triple screening enables interference-free operation of frequency converters
-Optimum compliance with requirements for electromagnetic compatibility (EMC)
 due to the triple  screening

Tests
:
-Flame-test, tested in acc. with
 DIN VDE 0472 part 804 test method B and IEC 60332-1
-Low mutual capacitance: tested acc. to DIN VDE 0472 part 504, test method B

Special features
:
Here the earth core cross-section is divided into thirds, which lie in the interstices between the power supply cores. Due to this symmetrical construction, the PE insulation and the triple screening, very low capacitance and inductance are achieved. EMC compatibility is considerably enhanced.

Application:



  Suitable as a supply and connecting cable for high mechanical stresses, in fixed installations and occasional free movements in dry, moist and wet environments, as well as outdoors.
• Machine Tools
• Processing and Manufacturing machinery
• Machining Centres
• Industrial Robots
• Transfer Lines
• Handling Equipment
Technical Data:
Special PUR motor power supply cable for frequency converter to UL AWM Style 20235
and CSA AWM based on DIN VDE 0250

Temperature Range
: flexing -30ºC to +80ºC      fixed installation -40ºC to +80ºC

Nominal voltage: acc. to UL 1000 V       acc. to VDE Uo/U 0,6/1 kV

A.c. test voltage: 50 Hz 3000 V

Mutual capacitance: at 4 kHz, depending on conductor cross-section core/core 70-250 nF/km core/screen 110-410 nF/km

InsulatIon resistance mm. 200 MOhm x km

Minimum bending radius:
fixed installation,
for outside ø to 12 mm = 5x cable ø
>12 to 20mm = 7.5x cable ø
>20 mm = 10x cable ø free-movement,
for outside 0 to 12 mm = 10x cable ø
>12 to 20mm = 15x cable ø
>20 mm = 20x cable ø

Coupling resistance: max. 250 Ohm/km

Radiation resistance: up to 80 x 106 cJ/kg (up to 80 Mrad)








  NYY-J & NYY-O
red_arroe MOTORFLEX-EMV 3/3
TOPFLEX-EMV-2YSLC-J
N2XSeY
N2XSY
1 Core Cu 5kv
1 Core Cu 15kv
1 Core Cu 35kv
PVC
XLPE