Description:
Single core and multi-core cables with copper conductors, PVC insulated, unarmoured or armoured and PVC sheathed. These cables are most suitable for underground burial
where there is a risk of mechanical damage. The cables are designed
for continuous operation
at a maximum conductor temperature of 70°C
Specification: According to MS274, BS 6346
Rated voltage : 600 / 1000V
Construction
Conductors: The conductors shall be circular stranded or sector shaped copper stranded wires.
Insulation: PVC compound type TI 1
Identification of cores: Single core - red or black Two-core - red and black Three-core - red,
yellow and blue Four-core - red, yellow, blue and black Five-core and above - (number) 1, 2, 3, 4, 5.... (auxiliary cables), and the numbers shall be blue or black printed on white cores.
Laying up (assembling): The cores of cables having two or more cores shall be laid up to form a compact and circular cable. Where necessary, non-hygroscopic fillers may be applied.
Bedding: Extruded black PVC Compound or lapped PVC tapes.
Armour: The armour shall consists of a single layer of galvanised steel wires.
Where single-core cables are armoured with non-magnetic material, such as aluminium wire.
Sheath: Black PVC compound type TM1. |
|
|
|
 |
|